MRC | Criteria | Characteristic |
---|
BHTQ | Pulse Rise Time Per Channel | 5.000 NANOSECONDS NOMINAL OPERATING CHANNEL |
BHTR | Pulse Decay Time Per Channel | 10.000 NANOSECONDS MINIMUM OPERATING CHANNEL |
BHTT | Pulse Repetition Rate Per Channel | 500.000 KILOPULSES PER SECOND NOMINAL OPERATING CHANNEL |
BHTT | Pulse Repetition Rate Per Channel | 5.000 KILOPULSES PER SECOND NOMINAL OPERATING CHANNEL |
BHTT | Pulse Repetition Rate Per Channel | 500.000 PULSES PER SECOND NOMINAL OPERATING CHANNEL |
BHTT | Pulse Repetition Rate Per Channel | 5.000 MEGAPULSES PER SECOND NOMINAL OPERATING CHANNEL |
BJBQ | Operating Ac Frequency In Hertz | 50.0 MINIMUM 1ST VOLTAGE |
BJBP | Connection Type And Location | RECEPTACLE, COAXIAL FRONT |
AFBH | Individual Section Quantity | 2 |
BJBQ | Operating Ac Frequency In Hertz | 400.0 MAXIMUM 2ND VOLTAGE |
BHTD | Frequency Adjustment Type | STEPPED |
BHTS | Polarity Per Channel | NEGATIVE OPERATING CHANNEL |
BHTT | Pulse Repetition Rate Per Channel | 50.000 PULSES PER SECOND NOMINAL OPERATING CHANNEL |
BJBJ | Output Wave Shape | PULSE, TRIGGER |
BJBW | Connection Contact Type And Quantity | 5 RECEPTACLE, COAXIAL INTERNAL |
FAAZ | Phase | SINGLE |
BKFC | External Ac Operating Voltage In Volts | 115.0 MINIMUM 1ST VOLTAGE |
ABKW | Overall Height | 5.250 INCHES NOMINAL |
BKFC | External Ac Operating Voltage In Volts | 230.0 MAXIMUM 2ND VOLTAGE |
ZZZV | Fsc Application Data | SUPPORT OF AN/ARD-18 AND AN/AGM-69 COMPONENTS |
MRC | Decoded Requirement | Clear Text Reply |
RDAL | Reference Data And Literature | 33A1-8-630-1 |
AGTA | Basic Shape Style | RECTANGULAR OR SQUARE |
FCLS | Functional Classification | BB-1.1 |
AMQY | Installation Design | FREE-STANDING |
ALBM | Operating Control Method | MANUAL |
ABMK | Overall Width | 13.750 INCHES NOMINAL |
AQZF | Control Type | LOCAL |
NTRD | Entry Date | 91-02-19 |
BHSX | Circuit Construction Type | SOLID STATE |
ABHP | Overall Length | 16.750 INCHES NOMINAL |
AKNA | Inclosure Type | ENCASED |
AFSU | Average Life Measurement | NOT RATED |
BHTB | Frequency Per Channel | 50.0 MEGAHERTZ MAXIMUM OPERATING CHANNEL |
BHTF | Individual Step Frequency | 5.0 HERTZ AND 500.0 HERTZ AND 5.0 KILOHERTZ AND 50.0 KILOHERTZ AND 500.0 KILOHERTZ AND 5.0 MEGAHERTZ |
BHTB | Frequency Per Channel | 5.0 HERTZ MINIMUM OPERATING CHANNEL |
BHTR | Pulse Decay Time Per Channel | 50.000 MILLISECONDS MAXIMUM OPERATING CHANNEL |
BHTS | Polarity Per Channel | POSITIVE OPERATING CHANNEL |
BHTT | Pulse Repetition Rate Per Channel | 50.000 KILOPULSES PER SECOND NOMINAL OPERATING CHANNEL |
BHTT | Pulse Repetition Rate Per Channel | 50.000 MEGAPULSES PER SECOND NOMINAL OPERATING CHANNEL |
BHTZ | Signal Data Type Per Channel | OPERATING CHANNEL PULSE |
BJBL | Indicator Device Type And Quantity | 6 LIGHT |