We appreciate your interest in part number EPC-11486, which is currently available for purchase here on Jet Force Aero. For your reference, this item is produced by Artisan Controls Corporation and is listed with the NSN 5945-01-107-5134, as well as the description “Relay Electromagnetic.” If this matches your requirements, we encourage you to fill out the Request for Quote (RFQ) form featured on this page to receive tailored purchasing options on part number EPC-11486. All that we ask is that you submit as many details about your procurement needs as possible, such as your desired quantity, budget, and anticipated fulfillment timeframe, as this will enable our specialists to craft an ideal response for you.
Note : We Will Not Share Your Information To Any Third Parties.
In addition to part number EPC-11486, be sure to explore our website further for related items produced by Artisan Controls Corporation under the CAGE Code 0AGK2 as you wish. We also feature catalogs to help you find additional options that are categorized under FSC 5945 Relays and Solenoids and the NSN 5945-01-107-5134. Regardless of which NSN parts you need from us, rest assured that we will always treat you to affordable solutions where you never have to sacrifice quality or prompt fulfillment. We are ready to assist you with all your sourcing needs, so kick off quotation at your convenience.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5945-01-107-5134 Item Description: Relay Electromagnetic | 5945 | 011075134 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Epc-11486 | 2 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 2.250 INCHES MINIMUM" |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.090 INCHES NOMINAL SINGLE MOUNTING FACILITY" |
ABKW | OVERALL HEIGHT | 0.880 INCHES MAXIMUM" |
ABMK | OVERALL WIDTH | 1.590 INCHES NOMINAL" |
ADTV | CASE MATERIAL | STEEL, CORROSION RESISTING" |
ADZC | ENVIRONMENTAL PROTECTION | VIBRATION RESISTANT AND SHOCK RESISTANT AND HUMIDITY RESISTANT AND SALT SPRAY RESISTANT AND HERMETIC" |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.159 INCHES NOMINAL SINGLE MOUNTING FACILITY" |
AKDX | WINDING QUANTITY | 1" |
APCN | COIL QUANTITY | 1" |
APNP | DUTY TYPE | CONTINUOUS" |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 3 UNTHREADED HOLE SINGLE MOUNTING FACILITY" |
CQYJ | MOUNTING FACILITY PATTERN | TRIANGLE SINGLE MOUNTING FACILITY" |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY" |
CRXH | TIME DELAY | 0.50 SECONDS MINIMUM FIXED RELEASE TIME AND 2.00 SECONDS MAXIMUM FIXED RELEASE TIME" |
CRXH | TIME DELAY | 10.00 SECONDS MINIMUM FIXED OPERATE TIME" |
CSQJ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO THE ALTITUDE OF AN ISOSCELES TRIANGLE | 1.750 INCHES MAXIMUM SINGLE MOUNTING FACILITY" |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 32.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING" |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 2.0 AMPERES DC RESISTIVE LOAD" |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 32.0 DC" |
CWJB | ENERGIZING ELEMENT POWER RATING | 4.0 WATTS" |
TTQY | TERMINAL TYPE AND QUANTITY | 4 WIRE HOOK DUMMY" |
TTQY | TERMINAL TYPE AND QUANTITY | 5 WIRE HOOK ENERGIZING ELEMENT AND CONTACTS" |
ABHP | OVERALL LENGTH | 2.250 INCHES MINIMUM" |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.090 INCHES NOMINAL SINGLE MOUNTING FACILITY" |
ABKW | OVERALL HEIGHT | 0.880 INCHES MAXIMUM" |
ABMK | OVERALL WIDTH | 1.590 INCHES NOMINAL" |
ADTV | CASE MATERIAL | STEEL, CORROSION RESISTING" |
ADZC | ENVIRONMENTAL PROTECTION | VIBRATION RESISTANT AND SHOCK RESISTANT AND HUMIDITY RESISTANT AND SALT SPRAY RESISTANT AND HERMETIC" |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.159 INCHES NOMINAL SINGLE MOUNTING FACILITY" |
AKDX | WINDING QUANTITY | 1" |
APCN | COIL QUANTITY | 1" |
APNP | DUTY TYPE | CONTINUOUS" |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 3 UNTHREADED HOLE SINGLE MOUNTING FACILITY" |
CQYJ | MOUNTING FACILITY PATTERN | TRIANGLE SINGLE MOUNTING FACILITY" |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY" |
CRXH | TIME DELAY | 0.50 SECONDS MINIMUM FIXED RELEASE TIME AND 2.00 SECONDS MAXIMUM FIXED RELEASE TIME" |
CRXH | TIME DELAY | 10.00 SECONDS MINIMUM FIXED OPERATE TIME" |
CSQJ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO THE ALTITUDE OF AN ISOSCELES TRIANGLE | 1.750 INCHES MAXIMUM SINGLE MOUNTING FACILITY" |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 32.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING" |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 2.0 AMPERES DC RESISTIVE LOAD" |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 32.0 DC" |
CWJB | ENERGIZING ELEMENT POWER RATING | 4.0 WATTS" |
TTQY | TERMINAL TYPE AND QUANTITY | 4 WIRE HOOK DUMMY" |
TTQY | TERMINAL TYPE AND QUANTITY | 5 WIRE HOOK ENERGIZING ELEMENT AND CONTACTS" |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.